全部替代型号
查看完整报告技术参数
| 电源 | |
|---|---|
| Current | I o | 8 mA |
| Current I o | 21 mA |
| Current output | max. 20 µA |
| Current range | 0 ... 20 mA or 4 ... 20 mA |
| Input/Other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Interface/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff |
| Maximum safe voltage | U m | 40 V DC (Attention! The rated voltage can be lower.) |
| Maximum safe voltage U m 40 V (Attention! The rated voltage can be lower.) | Maximum safe voltage | U m | 40 V (Attention! The rated voltage can be lower.) |
| Maximum safe voltage U m 40 V (Attention! The rated voltage can be lower.) , RS 232 | Maximum safe voltage | U m | 40 V (Attention! The rated voltage can be lower.) , RS 232 |
| Maximum safe voltage U m 40 V DC (Attention! The rated voltage can be lower.) | Maximum safe voltage | U m | 40 V DC (Attention! The rated voltage can be lower.) |
| Measuring current | approx. 400 µA with resistance measuring sensor |
| Open loop voltage | max. 24 V DC |
| Output III/power supply and collective error | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff |
| Power | P o | 67 mW |
| Power dissipation/power consumption | ≤ 2 W / 2.2 W |
| Power P o | 67 mW |
| Rated current | I r | approx. 100 mA |
| Rated voltage | U r | 20 ... 30 V DC |
| Voltage | 0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV |
| Voltage U o | 13.1 V |
| Voltage U o 13.1 V Current I o 21 mA Power P o 67 mW | Voltage U o | 13.1 V | Current I o | 21 mA | Power P o | 67 mW |
| Voltage U o 13.1 V Current I o 8 mA Power P o 67 mW Voltage U i 29 V Current I i 11 mA Power P i 200 mW | Voltage | U o | 13.1 V | Current | I o | 8 mA | Power | P o | 67 mW | Voltage | U i | 29 V | Current | I i | 11 mA | Power | P i | 200 mW |
| 交流 / 直流特性 | |
| Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A Mechanical life 5 x 10 7 switching cycles Energized/De-energized delay approx. 20 ms / approx. 20 ms | Contact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A | Mechanical life | 5 x 10 7 switching cycles | Energized/De-energized delay | approx. 20 ms / approx. 20 ms |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms |
| Output I, II against eachother | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff |
| 环境与封装 | |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Temperature effect | Input: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span |
| 其他 | |
| Certificate | PF 08 CERT 1213 X |
| Cold junction compensation | external and internal |
| Cold junction compensation external and internal Measurement loop monitoring sensor breakage | Cold junction compensation | external and internal | Measurement loop monitoring | sensor breakage |
| Collective error message | Power Rail |
| Configuration | via operating buttons via PACTware |
| Connection | terminals 23+, 24- or power feed module/Power Rail |
| Connection side | field side |
| Contact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A |
| Contact loading 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load | Contact loading | 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load |
| Control elements | Control panel |
| Degree of protection | IEC 60529:2001 |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Directive 2014/30/EU EN 61326-1:2013 (industrial locations) | Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010 |
| Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010 | Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010 |
| Directive 2014/35/EU | EN 61010-1:2010 |
| Directive 2014/35/EU EN 61010-1:2010 | Directive 2014/35/EU | EN 61010-1:2010 |
| Display elements | LEDs , display |
| Electromagnetic compatibility | NE 21:2007 |
| EU-type examination certificate | TÜV 03 ATEX 2140 |
| Fault signal | downscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43) |
| IECEx certificate | IECEx TUN 09.0019 |
| IECEx certificate IECEx TUN 09.0019 IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I | IECEx certificate | IECEx TUN 09.0019 | IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
| Input | Ex ia |
| Input/Other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff |
| Input resistance | ≥ 250 kΩ (0 ... 10 V) min. 1 MΩ (0 ... 1 V, -100 ... 100 mV) |
| Inputs | terminals 1, 2, 3, 4, 6 (for passive equipment) |
| Labeling | space for labeling at the front |
| Lead resistance | max. 50 Ω |
| Load | max. 650 Ω |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I Input Ex ia | Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I | Input | Ex ia |
| Marking II 3G Ex nA nC IIC T4 Gc | Marking | II 3G Ex nA nC IIC T4 Gc |
| Mass | 300 g |
| Measurement loop monitoring | sensor breakage, sensor short-circuit |
| Mechanical life | 5 x 10 7 switching cycles |
| Output I, II | relay |
| Output III | Analog current output |
| Output I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff |
| Potentiometer | 0.8 ... 20 kΩ |
| Programming interface | programming socket |
| RTD | Pt100, Pt500, Pt1000, Ni100, Ni1000 |
| Safety Integrity Level (SIL) | SIL 2 |
| Sampling rate | approx. 700 ms |
| Signal type | Analog input |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Thermocouples | type B, E, J, K, L, N, R, S, T (IEC 584-1: 1995) |
| Types of measuring | 2-, 3-, 4-wire technology |
| Types of measuring 2-, 3-, 4-wire technology Lead resistance max. 50 Ω Measurement loop monitoring sensor breakage, sensor short-circuit | Types of measuring | 2-, 3-, 4-wire technology | Lead resistance | max. 50 Ω | Measurement loop monitoring | sensor breakage, sensor short-circuit |
| Types of measuring 2-, 3-, 5-wire technology | Types of measuring | 2-, 3-, 5-wire technology |
器件图片
技术资料
该型号暂未收录资料。