All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | < 25 mA at 24 V Operating voltage
Operating voltageU B | 18 ... 30 V DC
Switching currentmax. 100 mA , resistive load
Switching voltagemax. 30 V DC
Voltage dropU d | ≤ 1.5 V DC
AC and DC characteristics
Absolute accuracytyp. ± 20 mm (including influence of temperature)
Repeat accuracy< 3 mm
Resolution1 mm
Ripple10 % within the supply tolerance
Time delay before availabilityt v | < 900 ms
Environment and package
Ambient temperature-30 ... 60 °C (-22 ... 140 °F)
Height50.6 mm
Height 50.6 mm Width 15 mm Depth 41.7 mmHeight | 50.6 mm | Width | 15 mm | Depth | 41.7 mm
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Temperature influence< 0.25 mm/K
Other
Ambient light limit50000 Lux @ 2.5 m standard white 90 % 10000 Lux @ 2.5 m black 6 %
Analog outputWindow mode (rising ramp) 200 ... 5000 mm
Average data age3 ms (default), 6 ms , 12 ms , 25 ms , 50 ms , 100 ms , adjustable
Beam divergence2 mrad
CCC approvalCCC approval / marking not required for products rated ≤36 V
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
Connection300 mm fixed cable with M12 x 1, 4-pin connector
Control elementsTeach-In key
Degree of protectionIP67 / IP69 / IP69K
Depth41.7 mm
Device ID1121027 (0x111B03)
Device profileIdentification and Diagnosis - I&D Smart Sensor - SSP 4.2.1
Diagnostic Coverage (DC)0 %
Diameter of the light spot< 20 mm at 10 m
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3 as described in Laser Notice 56, dated May 8, 2019.
Function indicatorLED yellow: constantly on - switch output active constantly off - switch output inactive
HousingPC (Polycarbonate)
Housing PC (Polycarbonate) Optical face PMMAHousing | PC (Polycarbonate) | Optical face | PMMA
Interface typeIO-Link ( via C/Q = pin 4 )
IO-Link revision1.1
Laser class1
Laser safetyEN 60825-1:2014
Light sourcelaser diode
Light typemodulated visible red light
Load resistor> 1 kΩ voltage output ; ≤ 470 Ω current output
Massapprox. 37 g
Max. Motion velocity10 m/s
max. pulse energy< 1.3 nJ
Measured value output1 ms
Measuring methodPulse Ranging Technology (PRT)
Measuring range0.03 ... 10 m
Min. cycle time4 ms
Mission Time (T M )20 a
MTTF d> 300 a
NoteLASER LIGHT , DO NOT STARE INTO BEAM
Operation indicatorLED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode
Optical facePMMA
Output type1 voltage output: 0 ... 10 V , 12 bit
Process dataInput 6 Byte - measurement value 4 Byte - scaling factor 8 Bit - signal quality 2 Bit - switching signal 1 1 Bit - switching signal 2 1 Bit - diagnosis signals n Bit - additional signals n Bit Output 2 Bit - sensor control function 1 Bit - evaluation control function 1 Bit
Product standardEN 61000-6-2, EN 61000-6-3
Protection classIII
Pulse length4 ns
Recovery time2 ms
Recovery time 2 msRecovery time | 2 ms
Reference targetstandard white 90 %, 100 mm x 100 mm
Repetition rate300 kHz
Signal output1 push-pull output , 1 analog output , reverse polarity protected , overvoltage protected
SIO mode supportyes
Switching output 1Q1: switching signal high-active , Window mode 6000 ... 9000 mm
Switching typeThe default setting is: C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link U - Pin2: analog output 0 ... 10 V
Teach-in indicatorTeach-In : LED yellow/green; equiphase flashing; 2,5 Hz Teach Error:LED green/yellow non equiphase flashing; 8.0 Hz
Transfer rateCOM2 (38.4 kBit/s)
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Usage categoryDC-12 and DC-13
Vendor ID1 (0x0001)
Warm up time5 min
Wave length660 nm
Width15 mm

Documents

No documents are linked to this part yet.