All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 20 mA
Off-state currentI r | 0 ... 0.5 mA typ. 0.01 mA
Operating currentI L | 0 ... 200 mA
Operating voltageU B | 10 ... 30 V DC
Operating voltage indicatorLED, green
Rated impulse withstand voltageU imp | 2.5 kV
Rated insulation voltageU i | 230 V
Rated insulation voltage U i 230 V Rated impulse withstand voltage U imp 2.5 kVRated insulation voltage | U i | 230 V | Rated impulse withstand voltage | U imp | 2.5 kV
Voltage dropU d | ≤ 2 V
AC and DC characteristics
Switching frequencyf | 0 ... 100 Hz
Time delay before availabilityt v | 120 ms
Environment and package
Ambient temperature-25 ... 85 °C (-13 ... 185 °F)
Height55 mm
Height 55 mm Width 55 mm Length 128 mmHeight | 55 mm | Width | 55 mm | Length | 128 mm
Other
Actual operating distances r | 36 ... 44 mm
Assured operating distances a | 0 ... 32.4 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Connection typescrew terminals
Core cross sectionup to 2.5 mm 2
Degree of protectionIP68 / IP69K
Diagnostic Coverage (DC)0 %
Housing baseplastic
Housing materialPA/metal
HysteresisH | typ. 5 %
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Installationnon-flush
Length128 mm
Mass225 g
Maximum core cross-sectionwithout wire end ferrules 2.5 mm 2 , with connector sleeves 1.5 mm 2
Minimum core cross-sectionwithout wire end ferrules 0.5 mm 2 , with connector sleeves 0.34 mm 2
Mission Time (T M )20 a
MTTF d1310 a
NoteTightening torque: 1.8 Nm (housing)
Output polarityDC
Output typePNP
Protection classII
Rated operating distances n | 40 mm
Reduction factor r 3040.75
Reduction factor r Al0.39
Reduction factor r Brass0.45
Reduction factor r Cu0.37
Reverse polarity protectionreverse polarity protected
Sensing facePA
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 200 mA
Width55 mm

Documents

No documents are linked to this part yet.