电源
No-load supply currentI 0 | ≤ 15 mA
Operating voltageU B | 10 ... 30 V DC
Rated operating currentI e | 200 mA , short-circuit/overload protected
Voltage dropU d | ≤ 3 V
交流 / 直流特性
Repeat accuracy± 0.5 % of full-scale value
Response delayapprox. 100 ms
Switching frequencyf | ≤ 4 Hz
Transducer frequencyapprox. 170 kHz
环境与封装
Ambient temperature-25 ... 85 °C (-13 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Temperature influence± 1.5 % of full-scale value
其他
Adjustment range90 ... 800 mm
Beam widthmedium sound lobe
CCC approvalCCC approval / marking not required for products rated ≤36 V
Connection typecable PUR , 2 m , Polyether based
Core cross section4 x 0.19 mm 2
Dead band0 ... 70 mm
Degree of protectionIP68 / IP69K
Diameter18 mm
HousingStainless steel 1.4404 / AISI 316L
Housing Stainless steel 1.4404 / AISI 316L Transducer Stainless steel 1.4435 / AISI 316L Seal Cable seal : TPU , Elastollan 1185 A10 (FDA)Housing | Stainless steel 1.4404 / AISI 316L | Transducer | Stainless steel 1.4435 / AISI 316L | Seal | Cable seal : TPU , Elastollan 1185 A10 (FDA)
Input type1 program input operating distance 1: -U B ... +1 V, operating distance 2: +6 V ... +U B input impedance: > 4,7 kΩ program pulse: ≥ 1 s
Length55 mm
Length 55 mm Diameter 18 mmLength | 55 mm | Diameter | 18 mm
Mass90 g
OutputSwitch point A1: 90 mm Switch point A2: 800 mm Output mode: Window mode Output logic: normally open
Output type1 switching output E5, PNP NO/NC, programmable
Range hysteresisH | 1 % of the set operating distance
SealCable seal : TPU , Elastollan 1185 A10 (FDA)
Sensing range70 ... 800 mm
StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019
Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019
Standard target plate100 mm x 100 mm
TransducerStainless steel 1.4435 / AISI 316L

器件图片

技术资料