| 电源 | |
|---|---|
| Measuring plate not detected ≥ 3 mA at nominal voltage Measuring plate detected ≤ 1 mA at nominal voltage | Measuring plate not detected | ≥ 3 mA at nominal voltage | Measuring plate detected | ≤ 1 mA at nominal voltage |
| Nominal voltage | U o | 8.2 V (R i approx. 1 kΩ) |
| Operating voltage | U B | 5 ... 25 V |
| 交流 / 直流特性 | |
| Switching frequency | f | 0 ... 3000 Hz |
| 环境与封装 | |
| Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
| 其他 | |
| Assured operating distance | s a | 0 ... 1.62 mm |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Cable diameter 4.8 mm ± 0.2 mm Bending radius > 10 x cable diameter Material silicone Core cross section 0.34 mm 2 Length L 10 m | Cable diameter | 4.8 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | silicone | Core cross section | 0.34 mm 2 | Length | L | 10 m |
| Connection type | cable |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP68 |
| Diameter | 14 mm |
| Equipment protection level Da | IECEx PTB 11.0092X |
| Equipment protection level Gb | IECEx PTB 11.0092X |
| Equipment protection level Gb IECEx PTB 11.0092X Equipment protection level Da IECEx PTB 11.0092X Equipment protection level Mb IECEx PTB 11.0092X | Equipment protection level Gb | IECEx PTB 11.0092X | Equipment protection level Da | IECEx PTB 11.0092X | Equipment protection level Mb | IECEx PTB 11.0092X |
| Equipment protection level Gb PTB 00 ATEX 2049 X Equipment protection level Da PTB 00 ATEX 2049 X | Equipment protection level Gb | PTB 00 ATEX 2049 X | Equipment protection level Da | PTB 00 ATEX 2049 X |
| Equipment protection level Mb | IECEx PTB 11.0092X |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Installation | flush |
| Length | L | 10 m |
| Length 70 mm Diameter 14 mm | Length | 70 mm | Diameter | 14 mm |
| Material | silicone |
| Measuring plate detected | ≤ 1 mA at nominal voltage |
| Measuring plate not detected | ≥ 3 mA at nominal voltage |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2 | NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2 |
| Output type | NAMUR with safety function |
| Rated operating distance | s n | 2 mm |
| Reduction factor r 304 | 0.85 |
| Reduction factor r Al | 0.4 |
| Reduction factor r Cu | 0.3 |
| Sensing face | PBT |
| Standards | EN IEC 60947-5-2 |
| Switching function | Normally closed (NC) |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Use in the hazardous area | see instruction manuals |