35376

35376

在产

Xtra-Guard 3 18 AWG 6 Conductor is a preferred outdoor cable for direct burial that has 6 times the water resistance of PVC cable.

全部替代型号

查看完整报告

技术参数

电源
1) Voltage Rating300 V RMS
交流 / 直流特性
4) Characteristic Impedance67 Ω
环境与封装
1) Temperature Range-30 to 80°C
其他
1) CEEU Low Voltage Directive 2014/35/EU
(1) Color CodeAlpha Wire Color Code A
1) Component 16 X 1 PAIR
(1) Twists5.3 Twists/foot (min)
2) Bend Radius10X Cable Diameter
2) Cable Assembly6 Components Cabled
2) Mutual Capacitance32 pF/ft @1 kHz, Nominal
3) California Proposition 65This product may contain substances known to the State of California to cause Cancer or Reproductive Harm, but is exempt from labeling based on the Consent Judgement. See the Alpha Wire website for more information.
3) Ground Capacitance58 pF/ft @1 kHz, Nominal
3) Pull Tension163 Lbs, Maximum
3) ShieldAlum/Mylar Tape, 20% Overlap, Min.
4) Sunlight ResistanceYes
5) Direct BurialYes
5) Inductance0.18 μH/ft, Nominal
6) Conductor DCR7.1 Ω/1000ft @20°C, Nominal
7) OA Shield DCR5.3 Ω/1000ft @20°C, Nominal
a) Color(s)Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
a) Foil DirectionFoil Facing In
a) Twists2.1 Twists/foot (min)
b) Drain Wire18 (16/30) AWG Tinned Copper
b) OrientationComponents to be arranged from INSIDE LAYER to OUTSIDE LAYER
b) Ripcord1 End 810 Denier Nylon
c) Core WrapClear Mylar Tape, 20% Overlap, Min.
ColorBLACK-RED
c) Pair2/Cond Cabled Together
c) PrintALPHA WIRE-* P/N 35376 6PR 18 AWG XTRAGUARD(R) 3 80C 300 VOLTS CE ROHS (SEQ FOOTAGE) * = Factory Code
Electrical Properties(For Engineering purposes only)
PackagingFlange x Traverse x Barrel (inches)
Pair1

器件图片

技术资料