42264

42264

在产

HART Multiplexer

查看国产替代问 AI FAE

全部替代型号

查看完整报告

技术参数

电源
Common mode voltageup to 30 V
Input voltage range0.12 ... 1.5 V ss
Interface/field channels1000 V eff
Interface/power supply500 V rms
Leakage current< 3 µA at -20 ... 85 °C (-4 ... 185 °F)
Number of channels32
Output voltage≥ 400 mV ss (with the terminator resistance specified above)
Power dissipation0.7 W at 24 V
Power supply/field channels1000 V eff
Rated currentI r | 28 mA at 24 V , RS-485, quiescent current
Rated voltageU r | 20.4 ... 30 V DC via Termination Board
交流 / 直流特性
Impedancehigh impedance
Input impedance> 5 kΩ , according to HART specification
环境与封装
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Dimensions18 x 114 x 130 mm (0.7 x 4.5 x 5.1 inch) (W x H x D)
Mountingon termination board
其他
Address1 ... 31 , adjustable via DIP switch
Approved forClass I, Division 2, Groups A, B, C, D and non-explosion hazardous area
Carrier detect levelsignal > 0.12 V pp , carrier detection activated signal < 0.08 V pp , carrier detection not activated
CertificateCML 17 ATEX 3337X
Common mode clamping± 10 V , for transient or AC signals
Configurationvia DIP switches
ConformityHART field device input (revision 5 to 7)
ConnectionSL1: 1a, 1b(-); 2a, 2b(+)
Control elementsDIP switches at the housing side for: - secondary module address - baud rate - test mode on/off
CSA certificate1256050
CSA certificate 1256050 Approved for Class I, Division 2, Groups A, B, C, D and non-explosion hazardous areaCSA certificate | 1256050 | Approved for | Class I, Division 2, Groups A, B, C, D and non-explosion hazardous area
Data link typeHART primary and secondary
DC isolationdual capacitor each channel
Degree of protectionIEC 60529:2001
Device typeDC isolated bus device
Differential mode clamping± 5.2 V , for transient or AC signals
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)Directive 2014/30/EU | EN 61326-1:2013 (industrial locations)
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018
Display elementsLEDs LED PWR ON (power supply), one green LED LED HART TX (HART transmission), one yellow LED LED FAULT (lead fault), one red LED
Electromagnetic compatibilityNE 21:2012 For further information see system description.
Field multi point supportoption available upon request
IECEx certificateIECEx CML 17.0178X
IECEx certificate IECEx CML 17.0178X IECEx marking Ex ec IIC T4 GcIECEx certificate | IECEx CML 17.0178X | IECEx marking | Ex ec IIC T4 Gc
IECEx markingEx ec IIC T4 Gc
Labelingspace for labeling at the front
MarkingII 3G Ex ec IIC T4 Gc
Marking II 3G Ex ec IIC T4 GcMarking | II 3G Ex ec IIC T4 Gc
Massapprox. 140 g
Output resistance100 Ω or smaller, capacitive coupling
Relative humidity5 ... 95 %, non-condensing
Safety Integrity Level (SIL)SIL 3
Signal range0.12 V pp < signal < 1.5 V pp
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Terminating resistorexternal 230 ... 500 Ω standard (up to 1000 Ω possible)
Topologymulti point, primary module/secondary module connection
Transfer rate9600 MBit/s, 19200 MBit/s or 38400 MBit/s, selectable via switch
Transmit amplitude200 Ω load, 0.43 V pp < signal < 0.49 V pp 500 Ω load, 1.1 V pp < signal < 1.2 V pp
TypeRS-485 , differential pair and grounding

器件图片

技术资料

该型号暂未收录资料。