All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Nominal voltage | U o | 8.2 V (R i approx. 1 kΩ) |
| AC and DC characteristics | |
| Switching frequency | f | 0 ... 100 Hz |
| Environment and package | |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Height | 55 mm |
| Height 55 mm Width 55 mm Length 128 mm | Height | 55 mm | Width | 55 mm | Length | 128 mm |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Other | |
| A | 25 mm |
| A 25 mm | A | 25 mm |
| Assured operating distance | s a | 0 ... 32.4 mm |
| CML approval | on request |
| Connection type | Connector plug |
| Control drawing | 116-0451 |
| Degree of protection | IP67 / IP69K |
| Electromagnetic compatibility | NE 21:2012 |
| Equipment protection level Da | IECEx PTB 11.0021X |
| Equipment protection level Ga | IECEx PTB 11.0021X |
| Equipment protection level Ga IECEx PTB 11.0021X Equipment protection level Gb IECEx PTB 11.0021X Equipment protection level Da IECEx PTB 11.0021X | Equipment protection level Ga | IECEx PTB 11.0021X | Equipment protection level Gb | IECEx PTB 11.0021X | Equipment protection level Da | IECEx PTB 11.0021X |
| Equipment protection level Ga PTB 00 ATEX 2032 X Equipment protection level Gb PTB 00 ATEX 2032 X Equipment protection level Da PTB 00 ATEX 2032 X | Equipment protection level Ga | PTB 00 ATEX 2032 X | Equipment protection level Gb | PTB 00 ATEX 2032 X | Equipment protection level Da | PTB 00 ATEX 2032 X |
| Equipment protection level Gb | IECEx PTB 11.0021X |
| Hazardous Location | E501628 |
| Hazardous Location 2020322315002302 | Hazardous Location | 2020322315002302 |
| Housing base | metal |
| Housing material | PA |
| Hysteresis | H | 2 ... 20 % typ. 10 % |
| Installation | non-flush |
| Length | 128 mm |
| Measuring plate detected | ≤ 1 mA |
| Measuring plate not detected | min. 2.5 mA |
| Measuring plate not detected min. 2.5 mA Measuring plate detected ≤ 1 mA | Measuring plate not detected | min. 2.5 mA | Measuring plate detected | ≤ 1 mA |
| MTTF d | 2415 a |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2012 Standards EN IEC 60947-5-2 | NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Electromagnetic compatibility | NE 21:2012 | Standards | EN IEC 60947-5-2 |
| Number of pins | 4 |
| Ordinary Location | E87056 |
| Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0451 | Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0451 |
| Output type | NAMUR |
| Rated operating distance | s n | 40 mm |
| Reduction factor r 304 | 0.75 |
| Reduction factor r Al | 0.41 |
| Reduction factor r Brass | 0.46 |
| Reduction factor r Cu | 0.38 |
| Reverse polarity protection | reverse polarity protected |
| Sensing face | PA |
| Short-circuit protection | yes |
| Standards | EN IEC 60947-5-2 |
| Switching function | Normally closed (NC) |
| Switching state indicator | LED, yellow |
| Threading | M12 x 1 |
| Threading M12 x 1 Number of pins 4 | Threading | M12 x 1 | Number of pins | 4 |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Use in the hazardous area | see instruction manuals |
| Width | 55 mm |
Documents