| Power | |
|---|---|
| Nominal voltage | U o | 8.2 V (R i approx. 1 kΩ) |
| AC and DC characteristics | |
| Switching frequency | f | 0 ... 200 Hz |
| Environment and package | |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Other | |
| Actual operating distance | s r | 2.7 ... 3.3 mm typ. |
| Assured operating distance | s a | 0 ... 2.4 mm |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 6.8 mm ± 0.2 mm |
| Cable diameter 6.8 mm ± 0.2 mm Bending radius > 10 x cable diameter Material silicone Core cross section 0.75 mm 2 Length L 5 m | Cable diameter | 6.8 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | silicone | Core cross section | 0.75 mm 2 | Length | L | 5 m |
| Connection type | cable |
| Control drawing | 116-0454 |
| Core cross section | 0.75 mm 2 |
| Degree of protection | IP68 |
| Diagnostic Coverage (DC) | 0 % |
| Diameter | 18 mm |
| Equipment protection level Da | IECEx PTB 11.0092X |
| Equipment protection level Dc (tc) | IECEx TUR 21.0018X |
| Equipment protection level Ga | IECEx PTB 11.0092X |
| Equipment protection level Gb | IECEx PTB 11.0092X |
| Equipment protection level Gc (ec) | IECEx TUR 21.0017X |
| Equipment protection level Mb | IECEx PTB 11.0092X |
| Hazardous Location | E501628 |
| Hazardous Location 2020322315002308 2024322315005947 2024322315005860 | Hazardous Location | 2020322315002308 2024322315005947 2024322315005860 |
| Housing material | Crastin (PBT), black |
| Installation | flush in mild steel |
| Length | L | 5 m |
| Length 39 mm Diameter 18 mm | Length | 39 mm | Diameter | 18 mm |
| Material | silicone |
| Measuring plate detected | ≥ 3 mA |
| Measuring plate not detected | ≤ 1 mA |
| Measuring plate not detected ≤ 1 mA Measuring plate detected ≥ 3 mA | Measuring plate not detected | ≤ 1 mA | Measuring plate detected | ≥ 3 mA |
| Mission Time (T M ) | 20 a |
| MTTF d | 10660 a |
| Note | only for non-ferrous metal |
| Ordinary Location | E87056 |
| Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0454 | Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0454 |
| Output type | NAMUR with safety function |
| Rated operating distance | s n | 3 mm |
| Reduction factor r 304 | 0 |
| Reduction factor r Al | 1 |
| Reduction factor r Cu | 1 |
| Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
| Scope of delivery | Supplied with 2 nuts |
| Sensing face | Crastin (PBT), black |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally open (NO) |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Use in the hazardous area | see instruction manuals |