All alternatives

View full report

Technical parameters

Power
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
AC and DC characteristics
Switching frequencyf | 0 ... 100 Hz
Environment and package
Ambient temperature-40 ... 100 °C (-40 ... 212 °F)
Height40 mm
Height 40 mm Width 84 mm Length 84 mmHeight | 40 mm | Width | 84 mm | Length | 84 mm
Other
Assured operating distances a | 0 ... 32.4 mm
Connection (system side)screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm
Connection typescrew terminals
Core cross sectionup to 2.5 mm 2 , stripped insulation length: 7 mm
Degree of protectionIP68
Equipment protection level DaIECEx PTB 11.0092X
Equipment protection level GbIECEx PTB 11.0092X
Equipment protection level Gb IECEx PTB 11.0092X Equipment protection level Da IECEx PTB 11.0092X Equipment protection level Mb IECEx PTB 11.0092XEquipment protection level Gb | IECEx PTB 11.0092X | Equipment protection level Da | IECEx PTB 11.0092X | Equipment protection level Mb | IECEx PTB 11.0092X
Equipment protection level Gb PTB 00 ATEX 2049 X Equipment protection level Da PTB 00 ATEX 2049 XEquipment protection level Gb | PTB 00 ATEX 2049 X | Equipment protection level Da | PTB 00 ATEX 2049 X
Equipment protection level MbIECEx PTB 11.0092X
Housing materialPBT
Installationflush
Length84 mm
Measuring plate detected≤ 1 mA
Measuring plate not detectedmin. 3 mA
Measuring plate not detected min. 3 mA Measuring plate detected ≤ 1 mAMeasuring plate not detected | min. 3 mA | Measuring plate detected | ≤ 1 mA
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2
Output typeNAMUR with safety function
Rated operating distances n | 40 mm
Reduction factor r 3040.85
Reduction factor r Al0.4
Reduction factor r Cu0.3
Sensing facePBT
StandardsEN IEC 60947-5-2
Switching functionNormally closed (NC)
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals
Width84 mm

Documents

No documents are linked to this part yet.