redundant contact system for high switching reliability by double contacting self-cleaning contact system due to wiping contacting center-zero version (basic type 1075) for detecting 3 switching positions noiseless switching system large overtravel
All alternatives
View full reportTechnical parameters
| Environment and package | |
|---|---|
| rOHSConform | yes |
| storageTemperatureMax | 85 |
| storageTemperatureMin | -40 |
| Other | |
| additionalLabeling | year/week/day/hour of manuf. |
| bearingConnection | tinned |
| childrenSortBy | key |
| connectionSideMax | 85 |
| connectionSideMin | -40 |
| contactType | wiper contact |
| externalConnection | tinned |
| freePositionFPMax | 10.15 |
| index | 0 |
| insulationResistanceNewCondition | > 100 (500 V DC) |
| key | 5109 |
| mechanicalLifeEndurance | 200E3 |
| miscellaneous | with resistor circuit diagnostics switches |
| miscellaneousOverviewPageCatalogue | terminal side sealed |
| numberOfPoles | 1 |
| operatingPositionNOC | 8.95 ±0.3 Widerstandswechsel |
| overtravelMin | 1.8 |
| permissibleTotalTravelPosition | 6.85 |
| pretravelMax | 1.5 |
| productIndex | 00 |
| shockResistance | 50 |
| stockVersion | F |
| switchingFunction | Changeover switch (SPDT momentary) can be diagnosed |
| weight | 0.900 |
Documents
No documents are linked to this part yet.