Power
No-load supply currentI 0 | ≤ 20 mA
Operating currentI L | 0 ... 100 mA
Operating voltageU B | 10 ... 30 V DC
Voltage dropU d | ≤ 3 V
AC and DC characteristics
Switching frequencyf | 0 ... 1800 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Other
Alternating magnetic fieldB | 100 mT
Assured operating distances a | 0 ... 1.215 mm
Bending radius> 10 x cable diameter
Cable diameter3 mm + 0.3 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Colorgrey
Connection typecable
Constant magnetic fieldB | 100 mT
Core cross section0.14 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Diameter8 mm
Housing materialBrass, PTFE coated
HysteresisH | 1 ... 10 % typ. 5 %
Installationflush
LengthL | 2 m
Length 40 mm Diameter 8 mmLength | 40 mm | Diameter | 8 mm
MaterialPVC
Mission Time (T M )20 a
MTTF d2240 a
Number of cores3
Output polarityDC
Output typePNP
Rated operating distances n | 1.5 mm
Reduction factor r 3040.65
Reduction factor r Al0.3
Reduction factor r Cu0.25
Reverse polarity protectionreverse polarity protected
Sensing facePPS; Ryton R4
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA
Wire end ferrulesyes

Documents

No documents are linked to this part yet.