All alternatives

View full report

Technical parameters

Power
Current consumptionelectronic insert FEL61: ≤ 3.8 mA electronic insert FEL62: ≤ 10 mA, without load
Power consumptionelectronic insert FEL61: ≤ 2 VA electronic insert FEL62: ≤ 0.5 W electronic insert FEL64: ≤ 25 VA/< 1.3 W electronic insert FEL64DC: < 1.0 W electronic insert FEL68: acc. to IEC 60947-5-6 (NAMUR)
Rated voltageU r | electronic insert FEL61: 19 ... 253 V AC, 50/60 Hz electronic insert FEL62: 10 V DC ... 55 V DC electronic insert FEL64: 19 V AC ... 253 V AC50/60 Hz / 19 V DC ... 55 V DC electronic insert FEL64DC: 9 V DC ... 20 V DC electronic insert FEL68: switch amplifier acc. to IEC 60947-5-6 (NAMUR)
Environment and package
Ambient temperature-60 ... 70 °C (-76 ... 158 °F) For further information see technical information (TI).
Dimensionshousing: diameter max. 147 mm, heigth max. 163 mm temperature spacer, pressure-tight feed through: additional length 140 mm compact version: length depends on process connection short tube version: length 99 ... 118 mm, depends on process connection pipe extension: - length 117 ... 6000 mm, 316L - length 148 ... 3000 mm, Alloy C22 tuning fork: width 17.2 mm, fork width 10 mm, length 40 mm For further information see technical information (TI).
Influence of medium temperaturemax. +1.4 ... -2.6 mm (-50 ... 150 °C (-58 ... 302 °F))
Medium temperature-50 ... 150 °C (-58 ... 302 °F)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Thermal shock resistance≤ 120 K/s
Other
Altitude≤ 2000 m above MSL
Climate classIEC 60068-2-38 test Z/AD
Communicationencrypted
Configurationcommissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption
Connectiongland M20 thread M20 , G1/2 , NPT1/2 , NPT3/4 plug M12
Construction typedevice with tube extension
Control elementsswitches on the electronic insert
Corrosion resistanceacc. to ISA-71.04, severity level G3
CSA approvalsee instruction manuals
Degree of protectionIEC 60529 , NEMA 250
Densitymin. 0.5 g/cm 3 , optional 0.4 g/cm 3
Designationsee technical information (TI)
Detection rangemax. 25 m
Directive 2014/30/EUEN 61326
Directive 2014/30/EU EN 61326Directive 2014/30/EU | EN 61326
Directive 2014/35/EUEN 61010-1
Directive 2014/35/EU EN 61010-1Directive 2014/35/EU | EN 61010-1
Display elementsStandard: without display LED module VU120, optional Bluetooth module VU121, optional
Electromagnetic compatibilityNE 21
EU-type examination certificatesee instruction manuals
Function principlepoint level detection, maximum or minimum detection for liquids
Function testvia switches on the electronic insert test magnet , optional
Housingsingle compartment, aluminum, coated single compartment, 316L, cast single compartment, plastic dual compartment, L-shape, aluminum, coated
Hysteresistyp. 2.5 mm
IECEx approvalsee instruction manuals
Influence of medium densitysee technical information (TI)
Influence of medium pressuremax. 0 ... 2.6 mm (-1 ... 64 bar)
Installation positionany position
Installation position any positionInstallation position | any position
Interface typeBluetooth ® , optional
Massbasic weight: 0.65 kg the basic weight comprises: - sensor (compact) - electronic insert - housing: single compartment, plastic with cover - process connection: thread, G3/4 in addition to the basic weight: - modules: 0,1 kg - housing: single compartment, aluminum, coated: 0.8 kg, single compartment, 316L: 1.21 kg, dual compartment, L-shaped, aluminum, coated: 1.22 kg - temperature spacer: 0.6 kg - pressure-tight feed through: 0.7 kg - pipe extension: 1000 mm: 0.9 kg, 100 inch: 2.3 kg - plastic protective cover: 0.2 kg For further information see technical information (TI).
Materialsee technical information (TI)
Maximum measured errormax. ± 1 mm
Measured variablelimit level (limit value)
Measuring methodThe change in vibration frequency causes the device to switch.
Measuring rangedepends on installation location and the tube extension maxmum sensor length : 6 m
Medium densityadjustment on the electronic insert > 0,5 g/cm 3 or > 0,7 g/cm 3 (other on request)
Medium pressurep e = 0 ... 100 bar (0 ... 1450.4 psi) over the entire temperature range , exceptions see process connections
Output typeelectronic insert FEL61: 2-wire with test button electronic insert FEL62: 3-wire PNP with test button electronic insert FEL64: relay DPDT with test button electronic insert FEL64DC: relay DPDT with contact and test button electronic insert FEL68: 2-wire NAMUR with test button
Overspill protectionsee approval (ZE)
Process connectioncylindrical threads G3/4, G1 acc. to DIN ISO 228 G for installing in weld-in adapter cylindrical threads G3/4, G1 acc. to DIN ISO 228 G with flat seal conical threads NPT3/4, NPT1 acc. to ANSI B 1.20.3 conical threads R3/4, R1 acc. to EN 10226 flanges RF, RJF, FF from 1 inch acc. to ASME B16.5 flanges form A, B1, C, D, E from DN25 acc. to EN 1092-1 flanges RF from 10K 25A acc. to JIS B2220 Tri-Clamp from DN25 acc. to ISO 2852 For further information see technical information (TI).
Reference operating conditionsambient temperature: 23 °C (73 °F) process temperature: 23 °C (73 °F) density: 1 g/cm 3 (water) medium viscosity: 1 mPa·s process pressure: ambietn pressure/unpressurized sensor installation: verticaly from above density selection switch: > 0.7 g/cm 3 switch direction of sensor: uncovered to covered
Safety Integrity Level (SIL)SIL 3
SeriesVibracon LVL-M4
Shock resistanceIEC 60068-2-27
State of aggregationliquid
Supplementary documentationtechnical information (TI) manuals, brief instructions (BA, KA) instruction manuals Functional safety manuals (FY) Special documentation (SD)
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Surface qualityR a < 3.2 µm/126 µinch
Switch behaviourswitch-over for minimum/maximum residual current safety on electronic insert MAX = maximum safety: The output switches to the power fail response when the fork is covered. for use with overspill protection for example MIN = minimum safety: The output switches to the power fail response when the fork is exposed. for use with dry running protection for example
Switching pointsee section switch point
Test pressurePN = 64 bar (928 psi): test pressure = 1.5 x PN maximum 100 bar (1450 psi) depending on process connection selected PN = 100 bar (1450 psi): test pressure = 1.5 x PN maximum 150 bar (2175 psi) depending on process connection selected
Vibration resistanceEN 60068-2-64
Viscositymax. 10000 mm 2 /s (max. 10000 cSt)

Documents

No documents are linked to this part yet.