All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 10 mA |
| Off-state current | I r | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| Operating current | I L | 0 ... 200 mA |
| Operating voltage | U B | 7 ... 30 V |
| Voltage drop | U d | ≤ 2 V |
| AC and DC characteristics | |
| Switching frequency | f | 0 ... 1600 Hz |
| Time delay before availability | t v | ≤ 100 ms |
| Environment and package | |
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Other | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Assured operating distance | s a | 0 ... 6.48 mm |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 4.3 mm ± 0.1 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Color | black |
| Connection assembly | Deutsch housing DT04-3P-CE02 Deutsch contact AT60-16-0822 Deutsch wedge W3P |
| Connection type | fixed cable with plug |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP68 / IP69K |
| Diagnostic Coverage (DC) | 0 % |
| Diameter | 18 mm |
| E1 Type approval | 10R-04 |
| Housing material | brass, nickel-plated |
| Hysteresis | H | typ. 5% |
| Installation | flush |
| Length | L | 270 mm ± 10 mm |
| Length 35 mm Diameter 18 mm | Length | 35 mm | Diameter | 18 mm |
| Mass | 70 g |
| Material | PUR |
| Mission Time (T M ) | 20 a |
| MTTF d | 1484 a |
| Number of cores | 3 |
| Number of pins | 3 |
| Number of pins 3 Connection assembly Deutsch housing DT04-3P-CE02 Deutsch contact AT60-16-0822 Deutsch wedge W3P | Number of pins | 3 | Connection assembly | Deutsch housing DT04-3P-CE02 Deutsch contact AT60-16-0822 Deutsch wedge W3P |
| Output polarity | DC |
| Output type | PNP |
| Rated operating distance | s n | 8 mm |
| Reduction factor r 304 | 0.7 |
| Reduction factor r Al | 0.4 |
| Reduction factor r Brass | 0.45 |
| Reduction factor r Cu | 0.3 |
| Reverse polarity protection | reverse polarity protected |
| Scope of delivery | 2 self locking nuts in scope of delivery |
| Sensing face | PBT |
| Short-circuit protection | pulsing |
| Standards | EN 60947-5-2 |
| Standards EN 60947-5-2 | Standards | EN 60947-5-2 |
| Switching function | Normally open (NO) |
| Switching state indicator | LED, yellow |
| UL approval | cURus Recognized Load Type: General Purpose Circuitry: Class 2 Power Source Supply/Switching Voltage: 30 V DC Output Switching Current: 200 mA Further UL information see section "Additional Information" |
Documents
No documents are linked to this part yet.