All alternatives

View full report

Technical parameters

Power
powerSupply5 V DC +-0.25 V
AC and DC characteristics
accuracyToleranceUout [V] = 0.3 [V/bar] x applied pressure [bar] + 0.5 [V]
Environment and package
mediumTemperatureMax90
mediumTemperatureMin+2
storageTemperatureMax90
storageTemperatureMin-40
Other
additionalLabelingyear/week/day of manuf.
additionalSpecificationspressure-/filling level measurement
burstingPressure> 42 bar / 609 psi / 4.2 MPa
childrenSortBykey
connectionSideMax70
connectionSideMin-10
countryOfOriginTN
customsTariffNumber90262020
index0
key3105
measuringRange0-10 bar / 0-145 psi / 0-1 MPa
mediumheating water water
miscellaneousplugging flange
miscellaneousTableCatalogueplugging flange
outputSignalproportional: 0.5 V at 0 bar, 3.5 V at 10 bar
productIndex00
sensorDescriptionmaximum current consumption < 14 mA (12 mA typ.)
sensorTypeanalog pressure sensor
stockVersionP
switchingFunctionPressure sensor
typeOfFasteningswallow-tail guide
weight22.780

Documents