All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 20 mA (device)
Operating voltageU B | 10 ... 30 V DC
Switching currentmax. 200 mA , resistive load
Switching voltage≤ 30 V DC
Voltage dropU d | ≤ 3 V
AC and DC characteristics
Ripple10 %
Switching frequencyf | ≤ 300 Hz
Time delay before availabilityt v | ≤ 300 ms
Environment and package
Ambient temperature-25 ... 55 °C (-13 ... 131 °F)
Height64 mm
Height 64 mm Width 25 mm Depth 75 mmHeight | 64 mm | Width | 25 mm | Depth | 75 mm
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Other
Adjustment range2 ... 25 m
Ambient light limitIEC / EN 60947-5-2 , 10000 Lux
ApprovalsCE
Connectionterminal compartment PG9 , ≤ 0.75 mm 2
Control elementsSensing range adjuster, light-on/dark-on changeover switch
Degree of protectionIP54
Depth75 mm
Diagnostic Coverage (DC)0 %
Effective detection range0 ... 20 m
EmitterLD39/116
Function indicatorLED yellow: switching state (receiver) LED red: pre-fault indicator, flashing (receiver)
HousingPBT
Housing PBT Optical face PMMAHousing | PBT | Optical face | PMMA
Light sourceLED
Light typemodulated infrared light
MassEmitter: approx. 90 g receiver: approx. 100 g
Mission Time (T M )20 a
MTTF d800 a
Operation indicatorLED red (emitter)
Optical facePMMA
Product standardEN 60947-5-2
ReceiverLV39/30/40a/116/126a
Reference targetreceiver
Response time≤ 1.5 ms
Scope of deliveryMounting aid
Signal output1 NPN output, short-circuit protected, reverse polarity protected, open collector
Stability alarm output1 NPN, active when falling short of operating reserve
Switching typelight/dark on
Threshold detection range25 m
Width25 mm

Documents

No documents are linked to this part yet.