All alternatives

View full report

Technical parameters

Power
Momentary current (20 ms, 0.1 Hz)0 ... 1600 mA
Off-state currentI r | 0 ... 1.7 mA
Operating currentI L | 5 ... 200 mA
Operating voltageU B | 20 ... 253 V
Operating voltage indicatorLED, green
Voltage dropU d | < 5 V (I L > 50 mA); < 8 V (I L < 50 mA)
AC and DC characteristics
Switching frequencyf | 0 ... 20 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Other
Actual operating distances r | 13.5 ... 16.5 mm
Assured operating distances a | 0 ... 12.15 mm
Bending radius> 10 x cable diameter
Cable diameter6.4 mm ± 0.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Colorgrey
Connection typecable
Core cross section0.75 mm 2
CSA approvalcCSAus Listed, General Purpose
Degree of protectionIP67
Diameter30 mm
Housing materialbrass, nickel-plated
HysteresisH | 1 ... 10 % typ. 5 %
Installationquasi flush
LengthL | 2 m
Length 50 mm Diameter 30 mmLength | 50 mm | Diameter | 30 mm
MaterialPVC
Note1) In the temperature range below 0 °C, permissible operating voltage U b 80...253 V Safety fuse ≤ 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
Number of cores3
Output polarityAC
Output typeTwo-wire
Rated operating distances n | 15 mm
Reduction factor r 3040.81
Reduction factor r Al0.33
Reduction factor r Cu0.28
Reverse polarity protectionreverse polarity tolerant
Sensing facePBT
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: Resistive Enclosure Type Rating: Type 1
Wire end ferrulesyes

Documents

No documents are linked to this part yet.