All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 15 mA |
| Off-state current | I r | ≤ 10 µA |
| Operating current | I L | 0 ... 100 mA |
| Operating voltage | U B | 5 V -5% +10% |
| Voltage drop | U d | ≤ 1.5 V |
| AC and DC characteristics | |
| Switching frequency | f | 0 ... 800 Hz |
| Time delay before availability | t v | ≤ 20 ms |
| Environment and package | |
| Ambient temperature | 15 ... 35 °C (59 ... 95 °F) |
| Height | 4.7 mm |
| Height 4.7 mm Width 8 mm Length 16 mm | Height | 4.7 mm | Width | 8 mm | Length | 16 mm |
| Other | |
| Assured operating distance | s a | 0 ... 1.8 mm |
| Connection assembly | AMP socket housing 103653-04 AMP crimp 5-104506-6 |
| Connection type | flexible leads PVC , 200 mm , twisted |
| Core cross section | 0.08 mm 2 |
| Degree of protection | IP67 |
| Diagnostic Coverage (DC) | 0 % |
| Housing material | PA |
| Hysteresis | H | typ. 5 % |
| Installation | non-flush |
| Length | 16 mm |
| Mission Time (T M ) | 20 a |
| MTTF d | 4830 a |
| Output polarity | DC |
| Output type | PNP |
| Rated operating distance | s n | 2 mm |
| Reduction factor r 304 | 0.7 |
| Reduction factor r Al | 0.3 |
| Reduction factor r Cu | 0.2 |
| Reverse polarity protection | no |
| Sensing face | PA |
| Short-circuit protection | pulsing |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally open (NO) |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 5 V DC Output Switching Current: 100 mA |
| Width | 8 mm |
Documents
No documents are linked to this part yet.