All alternatives

View full report

Technical parameters

Power
1) Voltage Rating300 V RMS
AC and DC characteristics
4) Characteristic Impedance65 Ω
Environment and package
1) Temperature Range-30 to 80°C
Other
1) CEEU Low Voltage Directive 2014/35/EU
(1) Color CodeAlpha Wire Color Code B
1) Component 12 X 1 PAIR
(1) Twists9.6 Twists/foot (min)
2) Bend Radius10X Cable Diameter
2) Cable Assembly2 Components Cabled
2) Mutual Capacitance27 pF/ft @1 kHz, Nominal
3) California Proposition 65This product may contain substances known to the State of California to cause Cancer or Reproductive Harm, but is exempt from labeling based on the Consent Judgement. See the Alpha Wire website for more information.
3) Ground Capacitance49 pF/ft @1 kHz, Nominal
3) Pull Tension20.9 Lbs, Maximum
3) ShieldA/P/A Tape, 25% Overlap, Min.
4) Sunlight ResistanceYes
5) Direct BurialYes
5) Inductance0.19 μH/ft, Nominal
6) Conductor DCR26 Ω/1000ft @20°C, Nominal
7) OA Shield DCR4.1 Ω/1000ft @20°C, Nominal
a) Color(s)Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
a) Drain Wire24 (7/32) AWG Tinned Copper
a) Twists6.0 Twists/foot (min)
b) BraidTinned Copper,70% Coverage, Nom.
b) OrientationComponents to be arranged from INSIDE LAYER to OUTSIDE LAYER
b) Ripcord1 End 810 Denier Nylon
c) Core WrapClear Mylar Tape, 25% Overlap, Min.
ColorWHITE-BLACK
c) Pair2/Cond Cabled Together
c) PrintALPHA WIRE-* P/N 35272 2PR 24 AWG XTRAGUARD(R) 3 80C 300 VOLTS CE ROHS (SEQ FOOTAGE) * = Factory Code
Electrical Properties(For Engineering purposes only)
PackagingFlange x Traverse x Barrel (inches)
Pair1