All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Power supply | 5V+-10% |
| AC and DC characteristics | |
| Max. scanning frequency | 100.00 kHz |
| Environment and package | |
| Accuracy grade | 1.0 µm |
| Operating temperature | +10/+40 °C |
| Other | |
| Cable length | 1.50 m |
| Cable type | PUR Ø 5.1 mm |
| Connecting direction | axial |
| Electrical connection | D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin |
| Fault detection signal | for disturbance LOW |
| ID number | 375137-02 |
| Measuring length | 30 mm |
| Output signal | Square-wave signals, TTL levels with 10-fold interpolation |
| Pin configuration | D510107 |
| Plunger actuation | extended with compressed air |
| Protection rating | IP64 (EN60529) |
| Reference mark position | 5 mm |
| Reference pulse width | 90° |
| Signal period | 2.000 µm |
| Type of guide | ball-bush guide |
Documents
Catalog & SelectionCatalog & Selection · 6.5 MB · 2026-09-24Catalog & SelectionCatalog & Selection · 6.4 MB · 2026-09-24User ManualUser Manual · 1.1 MB · 2026-09-24Quality & ReliabilityQuality & Reliability · 1.0 MB · 2026-09-24Quality & ReliabilityQuality & Reliability · 850.9 KB · 2026-09-24User ManualUser Manual · 638.2 KB · 2026-09-24OtherOther · 265.8 KB · 2026-09-24Quality & ReliabilityQuality & Reliability · 60.9 KB · 2026-09-24