All alternatives

View full report

Technical parameters

Power
Average Power30 W Power handling is guaranteed with a source and load VSWR of 1.2:1
Peak Power3000 W Power handling is guaranteed with a source and load VSWR of 1.2:1
AC and DC characteristics
Frequency Max.18000 MHz
Frequency Min.6000 MHz
Environment and package
Specs Guaranteed Temp Max.23 °C
Specs Guaranteed Temp Min.23 °C
Other
Amplitude Balance (+/-)0.7 dB
DescriptionHYBRID COUPLER ASSY
Insertion Loss0.85 dB
Isolation14 dB
Phase Balance (+/-)6 Deg
Product CategoryHybrid Coupler
VSWR1.5 Ratio