All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 15 mA |
| Off-state current | I r | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| Operating current | I L | 0 ... 100 mA |
| Operating voltage | U B | 10 ... 30 V |
| Voltage drop | U d | ≤ 3 V |
| AC and DC characteristics | |
| Switching frequency | f | 500 Hz |
| Environment and package | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Height | 25.5 mm |
| Height 25.5 mm Width 25 mm Length 38.5 mm | Height | 25.5 mm | Width | 25 mm | Length | 38.5 mm |
| Other | |
| Assured operating distance | s a | 0 ... 5.67 mm |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 4.6 mm ± 0.2 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Color | grey |
| Connection type | cable |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP67 |
| Housing material | PBT |
| Hysteresis | H | typ. 5% |
| Installation | flush |
| Length | L | 2 m |
| Material | PVC |
| Number of cores | 3 |
| Output polarity | DC |
| Output type | NPN |
| Rated operating distance | s n | 7 mm |
| Reduction factor r 304 | 0.6 |
| Reduction factor r Al | 0.3 |
| Reduction factor r Cu | 0.2 |
| Reverse polarity protection | reverse polarity protected |
| Sensing face | PBT |
| Short-circuit protection | pulsing |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally open (NO) |
| Switching state indicator | LED, yellow |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA |
| Width | 25 mm |
| Wire end ferrules | yes |
Documents
No documents are linked to this part yet.