All alternatives

View full report

Technical parameters

Power
Lowest operating currentI m | 0 mA
No-load supply currentI 0 | ≤ 15 mA
Off-state currentI r | 0 ... 0.5 mA typ. 0.01 mA
Off-state current T U =40 °C, switching element off≤ 100 µA
Off-state current T U =40 °C, switching element off ≤ 100 µAOff-state current T U =40 °C, switching element off | ≤ 100 µA
Operating currentI L | 0 ... 100 mA
Operating voltageU B | 10 ... 30 V DC
Voltage dropU d | ≤ 2 V
AC and DC characteristics
Switching frequencyf | 0 ... 10 Hz
Time delay before availabilityt v | ≤ 50 ms
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Height5 mm
Height 5 mm Width 50 mm Length 25 mmHeight | 5 mm | Width | 50 mm | Length | 25 mm
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Assured operating distances a | 0 ... 3.5 mm
B0 mm
B 0 mm C 10 mm F 20 mm / 50 mmB | 0 mm | C | 10 mm | F | 20 mm / 50 mm
Bending radius> 10 x cable diameter
C10 mm
Cable diameter3.5 mm ± 0.2 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Colorgrey
Connection typecable
Core cross section0.14 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
F20 mm / 50 mm
Housing materialPBT
HysteresisH | 1 ... 10 % typ. 5 %
Installationnon-flush
LengthL | 2 m
MaterialPVC
Mission Time (T M )20 a
MTTF d1200 a
Number of cores3
Output polarityDC
Output typePNP
Rated operating distances n | 5 mm
Reverse polarity protectionreverse polarity protected
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
UL approvalcULus Listed Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA
Width50 mm
Wire end ferrulesyes

Documents