All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Inductive overvoltage protection | yes |
| No-load supply current | I 0 | ≤ 11 mA |
| Off-state current | I r | ≤ 10 µA |
| Operating current | I L | 0 ... 200 mA |
| Operating voltage | U B | 10 ... 30 V |
| Voltage drop | U d | ≤ 2 V |
| AC and DC characteristics | |
| Repeat accuracy | R | 0.6 mm |
| Ripple | 10 % |
| Switching frequency | f | 0 ... 500 Hz |
| Time delay before availability | t v | ≤ 50 ms |
| Environment and package | |
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Other | |
| A | in steel 1.0037 (St37): 4 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 36 mm x 36 mm x 1 mm |
| A in steel 1.0037 (St37): 4 mm B 14 mm C 36 mm F 36 mm | A | in steel 1.0037 (St37): 4 mm | B | 14 mm | C | 36 mm | F | 36 mm |
| Assured operating distance | s a | 0 ... 9.72 mm |
| B | 14 mm |
| Bending radius | > 10 x cable diameter |
| C | 36 mm |
| Cable diameter | 4.3 mm ± 0.2 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Color | black |
| Connection type | cable |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP67 |
| Diagnostic Coverage (DC) | 0 % |
| Diameter | 18 mm |
| F | 36 mm |
| Housing material | brass, nickel-plated |
| Hysteresis | H | 0.12 ... 1.8 mm |
| Installation | quasi flush |
| Length | L | 2 m |
| Length 53 mm Diameter 18 mm | Length | 53 mm | Diameter | 18 mm |
| Mass | 100 g |
| Material | PUR |
| Mission Time (T M ) | 20 a |
| MTTF d | 1940 a |
| Number of cores | 3 |
| Output polarity | DC |
| Output type | NPN |
| Overload resistance | yes |
| Rated operating distance | s n | 12 mm |
| Reduction factor r 304 | 0.63 |
| Reduction factor r Al | 0.26 |
| Reduction factor r Brass | 0.33 |
| Reduction factor r Cu | 0.2 |
| Reverse polarity protection | yes |
| Sensing face | PBT |
| Short-circuit protection | pulsing |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Surge suppression | yes |
| Switching function | Normally open (NO) |
| Switching state indicator | LED, yellow |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 200 mA |
| Wire breakage protection | yes |
| Wire end ferrules | yes |
Documents