All alternatives

View full report

Technical parameters

Power
Momentary current (20 ms, 0.1 Hz)max. 4000 mA
Off-state currentI r | ≤ 2 mA
Operating currentI L | 5 ... 500 mA
Operating voltageU B | 20 ... 253 V AC
Voltage dropU d | Typ. 4 V at 40 ... 500 mA load current Typ. 5 V at 15 ... 40 mA load current Typ. 7 V at 5 ... 15 mA load current
Voltage drop I L = 200 mA, switching element onU d | 3.5 V
Voltage drop I L = 200 mA, switching element on U d 3.5 VVoltage drop I L = 200 mA, switching element on | U d | 3.5 V
AC and DC characteristics
Switching frequencyf | 0 ... 25 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Height60 mm
Height 60 mm Width 30 mm Length 48 mmHeight | 60 mm | Width | 30 mm | Length | 48 mm
Other
Bending radius> 10 x cable diameter
Cable diameter6 mm ± 0.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Colorgrey
Connection typecable
Core cross section0.75 mm 2
Degree of protectionIP67
Depth of immersion (lateral)18.5 ... 20.5 mm
Diagnostic Coverage (DC)0 %
Housing materialPBT
HysteresisH | typ. 5%
LengthL | 2 m
MaterialPVC
Mission Time (T M )20 a
MTTF d1553 a
Note1) In the temperature range below 0 °C, permissible operating voltage U b 80...253 V Safety fuse ≤ 2 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
Number of cores2
Output polarityAC
Output typeTwo-wire
Slot width15 mm
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
UL approvalcULus Listed Load Type: Resistive Enclosure Type Rating: Type 1
Width30 mm
Wire end ferrulesyes

Documents

No documents are linked to this part yet.