| Power | |
|---|---|
| Momentary current (20 ms, 0.1 Hz) | max. 4000 mA |
| Off-state current | I r | ≤ 2 mA |
| Operating current | I L | 5 ... 500 mA |
| Operating voltage | U B | 20 ... 253 V AC |
| Voltage drop | U d | Typ. 4 V at 40 ... 500 mA load current Typ. 5 V at 15 ... 40 mA load current Typ. 7 V at 5 ... 15 mA load current |
| Voltage drop I L = 200 mA, switching element on | U d | 3.5 V |
| Voltage drop I L = 200 mA, switching element on U d 3.5 V | Voltage drop I L = 200 mA, switching element on | U d | 3.5 V |
| AC and DC characteristics | |
| Switching frequency | f | 0 ... 25 Hz |
| Environment and package | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Height | 60 mm |
| Height 60 mm Width 30 mm Length 48 mm | Height | 60 mm | Width | 30 mm | Length | 48 mm |
| Other | |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 6 mm ± 0.2 mm |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Color | grey |
| Connection type | cable |
| Core cross section | 0.75 mm 2 |
| Degree of protection | IP67 |
| Depth of immersion (lateral) | 18.5 ... 20.5 mm |
| Diagnostic Coverage (DC) | 0 % |
| Housing material | PBT |
| Hysteresis | H | typ. 5% |
| Length | L | 2 m |
| Material | PVC |
| Mission Time (T M ) | 20 a |
| MTTF d | 1553 a |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage U b 80...253 V Safety fuse ≤ 2 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
| Number of cores | 2 |
| Output polarity | AC |
| Output type | Two-wire |
| Slot width | 15 mm |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally open (NO) |
| UL approval | cULus Listed Load Type: Resistive Enclosure Type Rating: Type 1 |
| Width | 30 mm |
| Wire end ferrules | yes |