All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 15 mA
Off-state currentI r | 0 ... 50 µA typ. 5 µA
Operating currentI L | 0 ... 100 mA
Operating voltageU B | 10 ... 30 V DC
Voltage dropU d | ≤ 2 V
AC and DC characteristics
Repeat accuracyR | ≤ 1.5 mm
Switching frequencyf | 0 ... 100 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Height12 mm
Height 12 mm Width 25 mm Length 40 mmHeight | 12 mm | Width | 25 mm | Length | 40 mm
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Actual operating distances r | 13.5 ... 16.5 mm
Assured operating distances a | 0 ... 10.8 mm
B15 mm
B 15 mm C 30 mm F 45 mm / 60 mmB | 15 mm | C | 30 mm | F | 45 mm / 60 mm
Bending radius> 10 x cable diameter
C30 mm
Cable diameter4.8 mm ± 0.2 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Colorblack
Connection typecable
Core cross section0.34 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
F45 mm / 60 mm
Housing materialPBT
HysteresisH | 1 ... 10 % typ. 5 %
Installationnon-flush
LengthL | 2 m
MaterialPUR
Mission Time (T M )20 a
MTTF d941 a
NoteScrew-in depth of housing screws, max. 8 mm
Number of cores4
Output polarityDC
Output typeNPN
Pollution degree3
Potentiometersensitivity adjustment
Rated operating distances n | 15 mm
Reverse polarity protectionreverse polarity protected
Sensing facePBT
Short-circuit protectionpulsing I max ≤ 500 mA
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functioncomplementary
Switching state indicatorLED, yellow
Tightening torque, housing screws≤ 2 Nm
UL approvalcULus Listed Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA
Width25 mm
Wire end ferrulesyes

Documents

No documents are linked to this part yet.