All alternatives

View full report

Technical parameters

Power
CurrentI o | 13 mA
Current limitI max | 40 mA
Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Number of channels2
Open loop voltageU s | 23 V
Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
PowerP o | 33 mW (linear characteristic)
Power consumption1.85 W
Power dissipation1.3 W
Rated voltageU r | Use only in connection with the power supplies LB9***
Voltage8.2 V
Voltage U o 10 V Current I o 13 mA Power P o 33 mW (linear characteristic) Internal capacitance C i 1.2 nF Internal inductance L i 0 mHVoltage | U o | 10 V | Current | I o | 13 mA | Power | P o | 33 mW (linear characteristic) | Internal capacitance | C i | 1.2 nF | Internal inductance | L i | 0 mH
Voltage U o 24.2 V Current I o 108 mA Power P o 654 mW Internal capacitance C i 12 nF Internal inductance L i 0 mHVoltage | U o | 24.2 V | Current | I o | 108 mA | Power | P o | 654 mW | Internal capacitance | C i | 12 nF | Internal inductance | L i | 0 mH
Environment and package
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Height100 mm
Height 100 mm Width 16 mm Depth 102 mmHeight | 100 mm | Width | 16 mm | Depth | 102 mm
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Altitudemax. 2000 m
ATEX approvalEXA 16 ATEX 0025 X
Codingoptional mechanical coding via front socket
Connectionbackplane bus
Connection [2]volt-free contact
Connection NAMUR sensor Connection [2] volt-free contactConnection | NAMUR sensor | Connection [2] | volt-free contact
Damaging gasEN 60068-2-42
Degree of protectionIEC 60529
Depth102 mm
Directive 2014/30/EUEN 61326-1:2013
Directive 2014/30/EU EN 61326-1:2013Directive 2014/30/EU | EN 61326-1:2013
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010
Electromagnetic compatibilityNE 21
Environmental testEN 60068-2-14
EU-type examination certificateEXA 16 ATEX 0025X
Field deviceSolenoid Valve
Field device [2]audible alarm
Field device [3]visual alarm
Field device Solenoid Valve Field device [2] audible alarm Field device [3] visual alarmField device | Solenoid Valve | Field device [2] | audible alarm | Field device [3] | visual alarm
IECEx certificateIECEx EXA 16.0010X
IECEx certificate IECEx EXA 16.0010X IECEx marking Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] IIECEx certificate | IECEx EXA 16.0010X | IECEx marking | Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I
IECEx markingEx nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I
Interfacemanufacturer-specific bus to standard com unit
Internal capacitanceC i | 1.2 nF
Internal inductanceL i | 0 mH
Internal resistorR i | 1 kΩ
LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (O: output, I1: input 1, I2: input 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1)
Line fault detectioncan be switched on/off for each channel via configuration tool
MarkingII 3(1) G Ex nA [ia Ga] IIC T4 Gc [exsign] II (1) D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Marking II 3(1) G Ex nA [ia Ga] IIC T4 Gc [exsign] II (1) D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IMarking | II 3(1) G Ex nA [ia Ga] IIC T4 Gc [exsign] II (1) D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Massapprox. 150 g
Minimum pulse duration1 ms
Occupied slots1
Open-circuit< 0.35 mA
OutputEx ia
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Relative humidityEN 60068-2-78
Response time10 ms (depending on bus cycle time)
Shock resistanceEN 60068-2-27
Short-circuit< 360 Ω
Short-circuit < 50 Ω Open-circuit > 10 kΩShort-circuit | < 50 Ω | Open-circuit | > 10 kΩ
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Switching point/switching hysteresis1.2 ... 2.1 mA / ± 0.2 mA
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
UL approvalE106378
Vibration resistanceEN 60068-2-6
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Width16 mm