All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Operating current | I B | max. 4 A |
| Operating voltage | U B | max. 250 V AC/DC |
| Environment and package | |
| Ambient temperature | Body: -40 ... 90 °C (-40 ... 194 °F) cable, movable installation: -25 ... 80 °C (-13 ... 176 °F) cable, fixed installation: -25 ... 80 °C (-13 ... 176 °F) |
| Other | |
| Bending radius | > 10 x cable diameter, movable installation 5 x cable diameter, single bend |
| Body | TPU, black |
| Cable | PUR |
| Color | grey |
| Conductor construction | 19 x 0.15 mm ∅ |
| Connection 1 | socket |
| Connection 2 | cable end |
| Construction type 1 | straight |
| Contact carrier | HB |
| Contact carrier HB Housing V-2 | Contact carrier | HB | Housing | V-2 |
| Contact elements | spring-loaded contact socket |
| Contacts | CuSn / Au |
| Contacts CuSn / Au Contact surface Au Body TPU, black Cable PUR Slotted nut Diecast zinc Core insulation PP | Contacts | CuSn / Au | Contact surface | Au | Body | TPU, black | Cable | PUR | Slotted nut | Diecast zinc | Core insulation | PP |
| Contact surface | Au |
| Core insulation | PP |
| Cores | 4 x 0.34 mm 2 |
| Degree of protection | EN 60529:2000 |
| Degree of protection EN 60529:2000 Standards IEC 61076-2-101:2008 Flammability Grip: UL 94 | Degree of protection | EN 60529:2000 | Standards | IEC 61076-2-101:2008 | Flammability | Grip: UL 94 |
| Flammability | Grip: UL 94 |
| Housing | V-2 |
| Length | L | 0.5 m |
| Mass | 28 g |
| Note | with wire end ferrules |
| Number of pins | 4 + shield |
| Pin diameter | 1 mm |
| Pollution degree | 3 |
| Sheath diameter | ∅ 4.8 mm |
| Shield | grid covering 85 % |
| Slotted nut | Diecast zinc |
| Standards | IEC 61076-2-101:2008 |
| Threading 1 | M12 |
| Volume resistance | < 5 mΩ |
Documents
No documents are linked to this part yet.