All alternatives

View full report

Technical parameters

Power
1) Voltage Rating300 V RMS
Environment and package
1) Temperature Range-40 to 80°C
Other
(1) Color CodeAlpha Wire Color Code E
1) Component 16 X 1 COND
2) Bend Radius10X Cable Diameter
2) Cable Assembly6 Components Cabled
2) Capacitance30 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance54 pF/ft @1 kHz, Nominal
3) OtherHalogen-Free
3) Pull Tension26 Lbs, Maximum
3) ShieldAlum/Mylar Tape, 25% Overlap, Min.
4) CEEU Low Voltage Directive 2014/35/EU
4) Inductance0.17 μH/ft, Nominal
5) Conductor DCR24.1 Ω/1000ft @20°C, Nominal
6) OA Shield DCR19.6 Ω/1000ft @20°C, Nominal
a) 1000 FT12 x 5.94 x 5 Continuous length
a) Color(s)SLATE
a) Foil DirectionFoil Facing In
a) Twists6.9 Twists/foot (min)
AWM/STYLE 21460VW-1
b) 100 FT6.5 x 2 x 1.9 Continuous length
b) Drain Wire24 (7/32) AWG Tinned Copper
b) OrientationComponents to be arranged from INSIDE LAYER to OUTSIDE LAYER
b) Ripcord1 End 810 Denier Nylon
c) Core WrapNonwoven Polyester Tape, 25% Overlap, Min.
ColorBLACK
Cond1
c) PrintALPHA WIRE-* P/N 78126 6C 24 AWG ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1 C(RU) AWM I A/B FT1 80C 300V CE ROHS (SEQ FOOTAGE) * = Factory Code
Electrical Properties(For Engineering purposes only)
PackagingFlange x Traverse x Barrel (inches)

Documents