All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Momentary current (20 ms, 0.1 Hz) | 0 ... 3000 mA |
| Off-state current | I r | ≤ 1.5 mA |
| Operating current | I L | 5 ... 500 mA |
| Operating voltage | U B | 20 ... 300 V DC / 20 ... 253 V AC |
| Operating voltage indicator | LED, green |
| Rated impulse withstand voltage | U imp | 2.5 kV |
| Rated insulation voltage | U i | 230 V |
| Rated insulation voltage U i 230 V Rated impulse withstand voltage U imp 2.5 kV | Rated insulation voltage | U i | 230 V | Rated impulse withstand voltage | U imp | 2.5 kV |
| Rated operating voltage | U e | 24 ... 250 V DC / 24 ... 230 V AC |
| Voltage drop | U d | ≤ 5 V (typ. 2V) DC operation ≤ 8 V (typ. 2V) AC operation |
| AC and DC characteristics | |
| Switching frequency | f | AC, 0 ... 30 Hz DC, 0 ... 100 Hz |
| Time delay before availability | t v | ≤ 300 ms |
| Environment and package | |
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Height | 40 mm |
| Height 40 mm Width 40 mm Length 118 mm | Height | 40 mm | Width | 40 mm | Length | 118 mm |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Other | |
| Actual operating distance | s r | 36 ... 44 mm typ. 40 mm |
| Assured operating distance | s a | 0 ... 32.4 mm |
| Connection type | Connector plug |
| Degree of protection | IP67 |
| Diagnostic Coverage (DC) | 0 % |
| Error indicator | flashes when overcurrent |
| Housing base | metal / class I equipment with ground connection |
| Housing material | PA 6.6 / metal |
| Hysteresis | H | 1 ... 10 % typ. 5 % |
| Installation | non-flush |
| Length | 118 mm |
| Mass | 320 g |
| Mission Time (T M ) | 20 a |
| MTTF d | 540 a |
| Number of pins | 3 |
| Output polarity | AC/DC |
| Output type | Two-wire |
| Protection class | I |
| Rated operating distance | s n | 40 mm |
| Reduction factor r 304 | 0.73 |
| Reduction factor r Al | 0.37 |
| Reduction factor r Brass | 0.4 |
| Reduction factor r Cu | 0.3 |
| Reduction factor r Fe | 1 |
| Reverse polarity protection | reverse polarity tolerant |
| Sensing face | PA 6.6 |
| Short-circuit protection | pulsing |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally open (NO) |
| Switching state indicator | LED, yellow |
| Threading | 7/8 inch-16 UN |
| Threading 7/8 inch-16 UN Number of pins 3 | Threading | 7/8 inch-16 UN | Number of pins | 3 |
| UL approval | cULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1 Supply/Switching Voltage: 250 V AC / 273 V DC Output Switching Current: 500 mA Further UL information see section "Additional Information" |
| Width | 40 mm |