All alternatives

View full report

Technical parameters

Power
Momentary current (20 ms, 0.1 Hz)0 ... 3000 mA
Off-state currentI r | ≤ 1.5 mA
Operating currentI L | 5 ... 500 mA
Operating voltageU B | 20 ... 300 V DC / 20 ... 253 V AC
Operating voltage indicatorLED, green
Rated impulse withstand voltageU imp | 2.5 kV
Rated insulation voltageU i | 230 V
Rated insulation voltage U i 230 V Rated impulse withstand voltage U imp 2.5 kVRated insulation voltage | U i | 230 V | Rated impulse withstand voltage | U imp | 2.5 kV
Rated operating voltageU e | 24 ... 250 V DC / 24 ... 230 V AC
Voltage dropU d | ≤ 5 V (typ. 2V) DC operation ≤ 8 V (typ. 2V) AC operation
AC and DC characteristics
Switching frequencyf | AC, 0 ... 30 Hz DC, 0 ... 100 Hz
Time delay before availabilityt v | ≤ 300 ms
Environment and package
Ambient temperature-25 ... 85 °C (-13 ... 185 °F)
Height40 mm
Height 40 mm Width 40 mm Length 118 mmHeight | 40 mm | Width | 40 mm | Length | 118 mm
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Other
Actual operating distances r | 36 ... 44 mm typ. 40 mm
Assured operating distances a | 0 ... 32.4 mm
Connection typeConnector plug
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Error indicatorflashes when overcurrent
Housing basemetal / class I equipment with ground connection
Housing materialPA 6.6 / metal
HysteresisH | 1 ... 10 % typ. 5 %
Installationnon-flush
Length118 mm
Mass320 g
Mission Time (T M )20 a
MTTF d540 a
Number of pins3
Output polarityAC/DC
Output typeTwo-wire
Protection classI
Rated operating distances n | 40 mm
Reduction factor r 3040.73
Reduction factor r Al0.37
Reduction factor r Brass0.4
Reduction factor r Cu0.3
Reduction factor r Fe1
Reverse polarity protectionreverse polarity tolerant
Sensing facePA 6.6
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
Threading7/8 inch-16 UN
Threading 7/8 inch-16 UN Number of pins 3Threading | 7/8 inch-16 UN | Number of pins | 3
UL approvalcULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1 Supply/Switching Voltage: 250 V AC / 273 V DC Output Switching Current: 500 mA Further UL information see section "Additional Information"
Width40 mm

Documents