All alternatives

View full report

Technical parameters

Datasheet-verified parameters

20 items
ParameterValue and test conditionsSource
Rated current3 A @ 40°C (3.45 A @ 25°C)
Maximum continuous operating voltage250 VAC, 50/60 Hz; 250 VDC
Nominal operating voltage230 VAC
Operating frequencyDC to 400 Hz
Temperature range (operation and storage)-25°C to +100°C
Leakage current0.66 mA @ 250 VAC/50 Hz (0.38 mA @ 120 VAC/60 Hz)
Power Loss1.2 W @ 25°C/DC
Inductance2.5 mH (Tolerance: -30/+50%)
Capacitance Cx0.15 μF (Tolerance: ±20%)
Capacitance Cy4.7 nF (Tolerance: ±20%)
Resistance1000 kΩ (Tolerance: ±10%)
High potential test voltageP -> N 760 VAC for 2 sec (1 to 20 A types); P -> PE 2000 VAC for 2 sec
Overvoltage categoryII acc. IEC 60664-1
Pollution degree2 acc. IEC 60664-1
Altitude2000m (above derating applies)
FlammabilityTerminal plastic for -06/-08 version: UL 94 V-0
Certified toUL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
MTBF>1,250,000 h @ 40°C/230 V (Mil-HB-217F)
Package / Connection styleFaston 6.3 × 0.8 mm (spade/soldering)
Weight80 g

Documents