Power
Input Power100 W CW Max @ -55 to +85 °C, 1 KW Peak Min +85°C (1 µs Pulse Width, 0.1% Duty Cycle)
Leakage Power15 dBm Max @ 100 W CW
Power Handling100 W CW Max @ -55 to +85 °C, 1 KW Peak Min +85°C (1 µs Pulse Width, 0.1% Duty Cycle)
AC and DC characteristics
Frequency Max (GHz)18
Frequency Min (GHz)0.02
Frequency Range (GHz)0.02 to 18
Environment and package
Non-Operating Temperature-62°C to +95°C
Operating Temperature-55 °C to +85 °C
Size0.90" x 0.38" x 0.38" Max [22.9 mm x 9.7 mm x 9. 7mm] Excluding Connectors
Other
Altitude70, 000 FT
Connectors In/OutInput: SMA M Output: SMA Female
Export Classification (ECCN)EAR99
FinishGold Plated
Humidity100%
Input/Output VSWR1.5:1 Max
Insertion Loss (dB)2.6 dB Max @ -10 dBm
Limiting Threshold (P1dB)+5 dBm Min
P1dB Limiting Threshold (dBm)5 Min
Phase Matching±4º Goal ±5º Max per set
Recovery Time100 ns Max @ 100 W Peak Power
RF Leakage (dBm)15 Max @ 100 W CW
Shock15g, 11 ± 1 ms
StatusPreliminary
Vibration0.1 inchpp OR ± 10G, 5 ~ 500 Hz (Figure 2, Sheet 1 of 3, Curve IV)
Weight20 g [0.705 oz] Max

Documents