All alternatives

View full report

6 alternatives on file, including 1 Chinese alternatives. Sign in to view them.

Technical parameters

Datasheet-verified parameters

17 items
ParameterValue and test conditionsSource
Package1210
Operating Temperature-40 °C to +85 °C
GradeAEC-Q200
RoHSCompliant
Halogen FreeCompliant
Maximum Voltage30 Volts
Maximum Current10 Amps
Hold Current0.05 Amps at 23 °C
Trip Current0.15 Amps at 23 °C
Minimum Resistance2.80 Ohms at 23 °C
Maximum 1 Minute Resistance50.00 Ohms at 23 °C
Maximum Time to Trip0.25 Sec. at 23 °C
Tripped Power Dissipation1.50 Watts at 23 °C
cUL RecognitionE174545
TÜV RecognitionR50256634
Recommended Storage+40 °C max. / 70 % R.H. max.
ESD ClassificationClass 6 (per AEC-Q200-2, HBM)
All parameters (10)ExpandCollapse
Power
Tried Power Dissipation1.50 Watts
Environment and package
Operating Temperature-40 °C to +85 °C
Package1210
Other
Ihold0.05 Amps
Imax.10 Amps
Itrip0.15 Amps
Max.Time to Trip0.25 Sec.
Resistance R1max50.00 Ohms at 23 °C
Resistance Rmin2.80 Ohms at 23 °C
Vmax.30 Volts

Documents