All alternatives

View full report

Technical parameters

Power
Inrush current16 A
Inrush current duration10 s
Reference voltage20 V
Reference voltage 2 ohmic120 VAC
Reference voltage dc ohmic30 VDC
Reference voltage ohmic250 VAC
Switching current0,1 A
Switching current dc ohmic0,6 A
Switching current ohmic5 A
Environment and package
Height67 mm
MountingClip for 35 mm DIN rail, EN 60715
Operating temperature0 °C - 60 °C
Storage temperature-40 °C - 60 °C
Other
AC/DCAC;DC
CasingPlastic to UL94 V-0, light grey
CCCCQC
Connection3-pole clamp: Rigid wire cable 2.5 mm² (AWG 14) Stranded wire² 1.5 mm² (AWG 16)
Contact typeSnap-action contact
Depth38 mm
DesignChanger
Device typeHygrostat
NoteSwitching differential related to 50 % rH. Wire end ferrules must be used for connections with stranded wires.
Operating humidity≤95 % RH
Protection typeIP20
Service life>50000 cycles
Setting range35 % RH - 95 % RH
Storage humidity≤95 % RH
Switching capacityAC 5 A;DC 20 W
Switching differential4 % RH
Switching differential tolerance± 3 % RH
Torque0,5 Nm max.
Weight60 g
Width50 mm

Documents