Поиск аналогов электронных компонентов
103847
Pepperl+Fuchs, Inc.Германия

103847

Производится

Inductive sensor

Спросить AI FAE

Все аналоги

Полный отчёт

Технические параметры

Питание
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
Характеристики по постоянному и переменному току
Switching frequencyf | 0 ... 400 Hz
Условия эксплуатации и корпус
Ambient temperature-25 ... 85 °C (-13 ... 185 °F)
Другое
ANZEx18.3018X
Assured operating distances a | 0 ... 1.22 mm
Bending radius> 10 x cable diameter
Cable diameter4.8 mm ± 0.2 mm
Cable diameter 4.8 mm ± 0.2 mm Bending radius > 10 x cable diameter Material PVC Core cross section 0.34 mm 2 Length L 10 mCable diameter | 4.8 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | PVC | Core cross section | 0.34 mm 2 | Length | L | 10 m
CML approvalon request
Connection typecable
Control drawing116-0165
Control drawing 116-0165Control drawing | 116-0165
Core cross section0.34 mm 2
Degree of protectionIP66 / IP68
Diameter18 mm
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level Gb IECEx PTB 11.0037X Equipment protection level Da IECEx PTB 11.0037X Equipment protection level Mb IECEx PTB 11.0037XEquipment protection level Gb | IECEx PTB 11.0037X | Equipment protection level Da | IECEx PTB 11.0037X | Equipment protection level Mb | IECEx PTB 11.0037X
Equipment protection level Gb PTB 00 ATEX 2048 X Equipment protection level Da PTB 00 ATEX 2048 XEquipment protection level Gb | PTB 00 ATEX 2048 X | Equipment protection level Da | PTB 00 ATEX 2048 X
Equipment protection level MbIECEx PTB 11.0037X
Hazardous Location2020322315002255
Hazardous Location 2020322315002255Hazardous Location | 2020322315002255
Housing materialStainless steel 1.4305 / AISI 303
HysteresisH | typ. %
Installationflush
LengthL | 10 m
Length 50 mm Diameter 18 mmLength | 50 mm | Diameter | 18 mm
MaterialPVC
Measuring plate detected≤ 1 mA
Measuring plate not detectedmin. 3 mA
Measuring plate not detected min. 3 mA Measuring plate detected ≤ 1 mAMeasuring plate not detected | min. 3 mA | Measuring plate detected | ≤ 1 mA
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2
Operating pressure350 bar (5076.4 psi)
Output typeNAMUR
Rated operating distances n | 1.5 mm
Reduction factor r 3040.55
Reduction factor r Al0
Reduction factor r Cu0
Safety Integrity Level (SIL)SIL 2
Sensing faceCeramic
StandardsEN IEC 60947-5-2
Switching functionNormally closed (NC)
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals

Изображения

Документы