Поиск аналогов электронных компонентов
104209
Pepperl+Fuchs, Inc.Германия

104209

Производится

Inductive sensor

Подобрать аналогСпросить AI FAE

Все аналоги

Полный отчёт

Технические параметры

Питание
Lowest operating currentI m | 2 mA
Off-state currentI r | ≤ 200 µA
Operating currentI L | 2 ... 30 mA
Operating voltageU B | 4 ... 30 V
Voltage dropU d | ≤ 4 V
Характеристики по постоянному и переменному току
Switching frequencyf | 0 ... 150 Hz
Условия эксплуатации и корпус
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Другое
Actual operating distances r | 9 ... 11 mm typ.
Assured operating distances a | 0 ... 8.1 mm
Bending radius> 10 x cable diameter
Cable diameter4.8 mm ± 0.2 mm
Colorgrey
Connection typecable
Core cross section0.34 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Diameter30 mm
Equipment protection level Dc (tc)IECEx TUR 21.0018X
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level Gc (ec) IECEx TUR 21.0017X Equipment protection level Dc (tc) IECEx TUR 21.0018XEquipment protection level Gc (ec) | IECEx TUR 21.0017X | Equipment protection level Dc (tc) | IECEx TUR 21.0018X
Equipment protection level Gc (ec) TÜV 20 ATEX 8523 X Equipment protection level Dc (tc) TÜV 20 ATEX 8524 XEquipment protection level Gc (ec) | TÜV 20 ATEX 8523 X | Equipment protection level Dc (tc) | TÜV 20 ATEX 8524 X
Hazardous Location2024322315005977 2024322315005859
Hazardous Location 2024322315005977 2024322315005859Hazardous Location | 2024322315005977 2024322315005859
Hazardous Location 23-AV4BO-0236XHazardous Location | 23-AV4BO-0236X
Housing materialStainless steel 1.4305 / AISI 303
HysteresisH | 1 ... 10 % typ. 5 %
Installationflush
LengthL | 2 m
Length 61 mm Diameter 30 mmLength | 61 mm | Diameter | 30 mm
Mass150 g
MaterialPVC
Mission Time (T M )20 a
MTTF d1536 a
Number of cores2
Output polarityDC
Output typeTwo-wire with minimum off-state current
Rated operating distances n | 10 mm
Reduction factor r 3040.66
Reduction factor r Al0.32
Reduction factor r Cu0.3
Reverse polarity protectionyes
Scope of delivery2 self locking nuts in scope of delivery
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorall direction LED, yellow
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 30 mA
Use in the hazardous areasee instruction manuals
Wire end ferrulesyes

Изображения