Поиск аналогов электронных компонентов
90287
Pepperl+Fuchs, Inc.Германия

90287

Производится

Bullet WirelessHART Adapter

Подобрать аналогСпросить AI FAE

Все аналоги

Полный отчёт

Технические параметры

Питание
Output current3.2 ... 25 mA
Rated currentI r | < 1 mA , max. 25 mA
Rated voltageU r | 7 ... 30 V DC
Supplyloop power for field devices voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V
Условия эксплуатации и корпус
Ambient temperaturetemperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F)
Dimensions60.8 x 60.8 x 100 mm (l x w x h)
Height100 mm
Height 100 mm Diameter 60.8 mmHeight | 100 mm | Diameter | 60.8 mm
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Другое
Approved forIS Class I, II, III, Division 1, Groups A-G Class I, Zone 0, AEx ia IIC T6...T5 Ga Zone 20, AEx ia IIIC T95°C Da
CommunicationWirelessHART specifications - physical layer: IEEE 802.15.4.2006 - frequency band: 2.4 GHz (ISM band, licence free) - maximum transmit power: +10 dBm - outdoor transmission range: 235 m - communication standard: WirelessHART acc. to IEC 62591
Connection- 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point
Control drawing116-0425 (cFMus)
Control drawing 116-0425 (cFMus) Approved for IS Class I, II, III, Division 1, Groups A-G Class I, Zone 0, AEx ia IIC T6...T5 Ga Zone 20, AEx ia IIIC T95°C DaControl drawing | 116-0425 (cFMus) | Approved for | IS Class I, II, III, Division 1, Groups A-G Class I, Zone 0, AEx ia IIC T6...T5 Ga Zone 20, AEx ia IIIC T95°C Da
Control drawing 116-0425 (cFMus) Approved for IS Class I, II, III, Division 1, Groups A-G Ex ia IIC T6...T5 Ga Ex ia IIIC T95°C Da associated apparatus [Ex ia]Control drawing | 116-0425 (cFMus) | Approved for | IS Class I, II, III, Division 1, Groups A-G Ex ia IIC T6...T5 Ga Ex ia IIIC T95°C Da associated apparatus [Ex ia]
CSA approvalFM 17 NCA 0004 FM 17 CA 0102 X
Degree of protectionIEC 60529:2013
Diameter60.8 mm
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012
Directive 2014/53/EUEN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017
Directive 2014/53/EU EN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017 FCC CFR47 Part 15 B and C ANSI C63.4-2003 , FCC ID: X89-WA1101Directive 2014/53/EU | EN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017 | FCC CFR47 Part 15 B and C | ANSI C63.4-2003 , FCC ID: X89-WA1101
EU-type examination certificateFM 17 ATEX 0046 X
FCC CFR47 Part 15 B and CANSI C63.4-2003 , FCC ID: X89-WA1101
FM approvalFM 17 NUS 0010 FM 17 US 0191 X
IECEx certificateIECEx FMG 17.0020X
IECEx markingEx ia IIC T6...T5 Ga , Ex ia IIIC T95°C Da
Interfaceinternal antenna
MarkingII 1G Ex ia IIC T6...T5 Ga [exsign] II 1D Ex ia IIIC T95°C Da
Marking II 1G Ex ia IIC T6...T5 Ga [exsign] II 1D Ex ia IIIC T95°C DaMarking | II 1G Ex ia IIC T6...T5 Ga [exsign] II 1D Ex ia IIIC T95°C Da
Mass460 g
Materialaluminum alloy with polyurethane enamel paint
Number of devicesup to 8 HART field devices (depending on installation)
ProtocolHART 7.1, backward compatible
Protocol HART 7.1, backward compatible Number of devices up to 8 HART field devices (depending on installation)Protocol | HART 7.1, backward compatible | Number of devices | up to 8 HART field devices (depending on installation)
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Relative humiditymax. 100 %
StandardsIEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-11:2011 , IEC 60079-31:2013
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Изображения

Документы

К этому компоненту пока не привязаны документы.