Поиск аналогов электронных компонентов
48362
Pepperl+Fuchs, Inc.Германия

48362

Производится

Temperature Converter with Trip Values

Подобрать аналогСпросить AI FAE

Все аналоги

Полный отчёт

Технические параметры

Питание
CurrentI o | 8 mA
Current I o21 mA
Current outputmax. 20 µA
Current range0 ... 20 mA or 4 ... 20 mA
Input/Other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/Other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff
Maximum safe voltageU m | 40 V DC (Attention! The rated voltage can be lower.)
Maximum safe voltage U m 40 V (Attention! The rated voltage can be lower.)Maximum safe voltage | U m | 40 V (Attention! The rated voltage can be lower.)
Maximum safe voltage U m 40 V (Attention! The rated voltage can be lower.) , RS 232Maximum safe voltage | U m | 40 V (Attention! The rated voltage can be lower.) , RS 232
Maximum safe voltage U m 40 V DC (Attention! The rated voltage can be lower.)Maximum safe voltage | U m | 40 V DC (Attention! The rated voltage can be lower.)
Measuring currentapprox. 400 µA with resistance measuring sensor
Open loop voltagemax. 24 V DC
Output III/power supply and collective errorreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff
PowerP o | 67 mW
Power dissipation/power consumption≤ 2 W / 2.2 W
Power P o67 mW
Rated currentI r | approx. 100 mA
Rated voltageU r | 20 ... 30 V DC
Voltage0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV
Voltage U o13.1 V
Voltage U o 13.1 V Current I o 21 mA Power P o 67 mWVoltage U o | 13.1 V | Current I o | 21 mA | Power P o | 67 mW
Voltage U o 13.1 V Current I o 8 mA Power P o 67 mW Voltage U i 29 V Current I i 11 mA Power P i 200 mWVoltage | U o | 13.1 V | Current | I o | 8 mA | Power | P o | 67 mW | Voltage | U i | 29 V | Current | I i | 11 mA | Power | P i | 200 mW
Характеристики по постоянному и переменному току
Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A Mechanical life 5 x 10 7 switching cycles Energized/De-energized delay approx. 20 ms / approx. 20 msContact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A | Mechanical life | 5 x 10 7 switching cycles | Energized/De-energized delay | approx. 20 ms / approx. 20 ms
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Output I, II against eachotherreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff
Условия эксплуатации и корпус
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Temperature effectInput: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span
Другое
CertificatePF 08 CERT 1213 X
Cold junction compensationexternal and internal
Cold junction compensation external and internal Measurement loop monitoring sensor breakageCold junction compensation | external and internal | Measurement loop monitoring | sensor breakage
Collective error messagePower Rail
Configurationvia operating buttons via PACTware
Connectionterminals 23+, 24- or power feed module/Power Rail
Connection sidefield side
Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
Contact loading 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive loadContact loading | 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load
Control elementsControl panel
Degree of protectionIEC 60529:2001
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)Directive 2014/30/EU | EN 61326-1:2013 (industrial locations)
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010
Directive 2014/35/EUEN 61010-1:2010
Directive 2014/35/EU EN 61010-1:2010Directive 2014/35/EU | EN 61010-1:2010
Display elementsLEDs , display
Electromagnetic compatibilityNE 21:2007
EU-type examination certificateTÜV 03 ATEX 2140
Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43)
IECEx certificateIECEx TUN 09.0019
IECEx certificate IECEx TUN 09.0019 IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] IIECEx certificate | IECEx TUN 09.0019 | IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
InputEx ia
Input/Other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff
Input resistance≥ 250 kΩ (0 ... 10 V) min. 1 MΩ (0 ... 1 V, -100 ... 100 mV)
Inputsterminals 1, 2, 3, 4, 6 (for passive equipment)
Labelingspace for labeling at the front
Lead resistancemax. 50 Ω
Loadmax. 650 Ω
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I Input Ex iaMarking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I | Input | Ex ia
Marking II 3G Ex nA nC IIC T4 GcMarking | II 3G Ex nA nC IIC T4 Gc
Mass300 g
Measurement loop monitoringsensor breakage, sensor short-circuit
Mechanical life5 x 10 7 switching cycles
Output I, IIrelay
Output IIIAnalog current output
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V eff
Potentiometer0.8 ... 20 kΩ
Programming interfaceprogramming socket
RTDPt100, Pt500, Pt1000, Ni100, Ni1000
Safety Integrity Level (SIL)SIL 2
Sampling rateapprox. 700 ms
Signal typeAnalog input
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Thermocouplestype B, E, J, K, L, N, R, S, T (IEC 584-1: 1995)
Types of measuring2-, 3-, 4-wire technology
Types of measuring 2-, 3-, 4-wire technology Lead resistance max. 50 Ω Measurement loop monitoring sensor breakage, sensor short-circuitTypes of measuring | 2-, 3-, 4-wire technology | Lead resistance | max. 50 Ω | Measurement loop monitoring | sensor breakage, sensor short-circuit
Types of measuring 2-, 3-, 5-wire technologyTypes of measuring | 2-, 3-, 5-wire technology

Изображения

Документы

К этому компоненту пока не привязаны документы.