Поиск аналогов электронных компонентов
103802
Pepperl+Fuchs, Inc.Германия

103802

Производится

Inductive sensor

Спросить AI FAE

Все аналоги

Полный отчёт

Технические параметры

Питание
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
Характеристики по постоянному и переменному току
Switching frequencyf | 0 ... 100 Hz
Условия эксплуатации и корпус
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Height55 mm
Height 55 mm Width 55 mm Length 128 mmHeight | 55 mm | Width | 55 mm | Length | 128 mm
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Другое
A25 mm
A 25 mmA | 25 mm
Assured operating distances a | 0 ... 32.4 mm
CML approvalon request
Connection typeConnector plug
Control drawing116-0451
Degree of protectionIP67 / IP69K
Electromagnetic compatibilityNE 21:2012
Equipment protection level DaIECEx PTB 11.0021X
Equipment protection level GaIECEx PTB 11.0021X
Equipment protection level Ga IECEx PTB 11.0021X Equipment protection level Gb IECEx PTB 11.0021X Equipment protection level Da IECEx PTB 11.0021XEquipment protection level Ga | IECEx PTB 11.0021X | Equipment protection level Gb | IECEx PTB 11.0021X | Equipment protection level Da | IECEx PTB 11.0021X
Equipment protection level Ga PTB 00 ATEX 2032 X Equipment protection level Gb PTB 00 ATEX 2032 X Equipment protection level Da PTB 00 ATEX 2032 XEquipment protection level Ga | PTB 00 ATEX 2032 X | Equipment protection level Gb | PTB 00 ATEX 2032 X | Equipment protection level Da | PTB 00 ATEX 2032 X
Equipment protection level GbIECEx PTB 11.0021X
Hazardous LocationE501628
Hazardous Location 2020322315002302Hazardous Location | 2020322315002302
Housing basemetal
Housing materialPA
HysteresisH | 2 ... 20 % typ. 10 %
Installationnon-flush
Length128 mm
Measuring plate detected≤ 1 mA
Measuring plate not detectedmin. 2.5 mA
Measuring plate not detected min. 2.5 mA Measuring plate detected ≤ 1 mAMeasuring plate not detected | min. 2.5 mA | Measuring plate detected | ≤ 1 mA
MTTF d2415 a
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2012 Standards EN IEC 60947-5-2NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Electromagnetic compatibility | NE 21:2012 | Standards | EN IEC 60947-5-2
Number of pins4
Ordinary LocationE87056
Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0451Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0451
Output typeNAMUR
Rated operating distances n | 40 mm
Reduction factor r 3040.75
Reduction factor r Al0.41
Reduction factor r Brass0.46
Reduction factor r Cu0.38
Reverse polarity protectionreverse polarity protected
Sensing facePA
Short-circuit protectionyes
StandardsEN IEC 60947-5-2
Switching functionNormally closed (NC)
Switching state indicatorLED, yellow
ThreadingM12 x 1
Threading M12 x 1 Number of pins 4Threading | M12 x 1 | Number of pins | 4
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals
Width55 mm

Изображения

Документы

К этому компоненту пока не привязаны документы.